Is a Heat Pump Sufficient to Run Underfloor Heating?

Spread the love

All warmth pump types operate using comparable rules – by harvesting energy from the setting and ‘compressing’ it to a temperature that can be utilized for a home’s scorching water and heating needs.

Probably the most important single factor affecting the effectivity of a heat pump is the movement temperature that it’s requested to produce. The higher this temperature the more work the compressor has to do and the less environment friendly it becomes. As a result, a heating system that may operate with decrease move temperatures, reminiscent of underfloor heating which typically operates at around 55oC, permits the pump to maximize its effectiveness and decrease both its carbon production and the fuel costs for the homeowner.

When underfloor heating techniques are specifically designed to be fed by a heat pump, additional tubing and pompa de caldura more efficient flooring constructions can be used to allow even decrease circulation temperatures, typically 35oC – 45oC, whilst nonetheless achieving the required air temperature inside the property (averaging 21 oC in residing areas). As a result of smaller surface area of the heat emitter, a conventional radiator system requires a significantly higher circulate temperature to achieve the same inner air temperature. Consequently underfloor heating and warmth pumps are perfect companions as they are each nicely suited to the low temperatures involved in maximizing efficiency.

When working UFH with a GSHP, an open circulation climate compensated system is desirered, with an external sensor checking any deviation in out of doors temperature, comparing stream and return temperatures on the UFH, then adjusting accordingly.

Insulation, insulation, insulation!

With underfloor heating, warmth passes into the room from the floor and it’s therefore essential to reduce building heat loss, together with downward warmth losses into the ground or the ground below. Current adjustments to Half L of the Building Rules have targeted attention on the significance of insulation ranges within domestic dwellings and in a new building that meets the laws, there’ll at all times be an adequate level of flooring insulation, and in these circumstances pumps can present four to five kilowatts of free energy for every 1 kilowatt of electrical energy used to power them.

Often, the goal ought to be to insulate the building so that less than 50 watts of heating are required per sq. meter of ground space. This will then ensure that the UFH water temperatures will be kept to a minimum and the warmth pump can operate at a higher Coefficient of Performance (COP) -typically four – 5 for a ground supply unit. In general it’s more price effective to extend insulation levels than it is to put in a larger pump and buildings that exceed the necessities of Half L of the Building Rules are most suitable.

In principle, there’s nothing to prevent a warmth pump from working in a building with a higher heat loss, corresponding to a property that requires as much as eighty watts per square meter. Nevertheless, higher heat loss requires higher heating water temperatures from the warmth pump – typically fifty five°C reasonably than 35 – forty five°C, that means the heat pump’s COP might endure though the warmth pump should be sufficient to heat the property.